Call Us Now
TEL: +86 13386078659; Skype ID: Hanwei; WeChat: +8613386078659; QQ ID: 413882258.
Item No.:
TR-HTBX120Payment:
FOB/CIFProduct origin:
ChinaColor:
WhiteShipping port:
ShangHaiLead Time:
7Ultra Low Temperature Refrigerator can be used for vaccine storage !!!
Medical low temperature refrigerator Low temperature refrigerator Freezer refrigerator Vaccine Medicine refrigerator -25 degrees Medical freezer Experimental low temperature refrigerator Test low temperature box -25 to 60 degrees 105L-560L
First. This refrigerator is suitable for low-temperature storage of vaccine serum, research and cultivation of microorganisms, test and storage of medicines and other medical refrigeration applications:
This instrument is composed of famous brand compressor, condenser, filter, capillary tube, evaporator thermostat, digital display instrument, digital temperature control system, etc. This machine has fast cooling speed, low noise, safe and reliable use.
Temperature adjustable range: 0 to 25℃, -40℃, -50℃, -60℃, -80℃ or -4℃, etc.,
Internal volume: 115L, 160L, 190L, 260L, 330L, 450L, 560L, etc.,
There are vertical (with drawers) and horizontal options. The vertical -4℃ medical blood refrigerator has blood type markings on each layer.
Second. Main technical parameters:
1. Control temperature: 0--25℃ Digital display thermostat display temperature (optional 0-10℃, -40℃, -50℃, -60℃, -80℃, etc.)
2. Voltage: 220V±10%V 50HZ
3. Uniformity: ≤2℃
4. Motor power: 130W (depending on temperature and volume)
5. Ambient temperature: 0-23℃
6. Internal volume: 115L (160L, 190L, 260L, 330L, 450L, 560L, etc. are optional)
7. Relative humidity: ≤75%
8. Wall thickness: 70mm, good insulation performance
The refrigerators dimension are as follows:
Capacity | Volume size (mm) | Dimension(mm) |
115L | 470*425*490 | 590*600*800 |
160L | 735*425*470 | 870*600*850 |
190L | 890*410*470 | 1045*564*880 |
218L | 905*430*480 | 1036*626*940 |
238L | 1018*425*480 | 1145*626*940 |
260L | 890*410*710 | 1070*600*820 |
288L | 1220*455*485 | 1270*690*912 |
302L | 1030*470*650 | 1145*710*880 |
338L | 1147*500*530 | 1270*690*952 |
368L | 1150*498*720 | 1270*690*912 |
520L | 1530*525*700 | 1754*780*965 |
Vertical 80L drawer | 360*360*660 | 500*510*840 |
Vertical 198L drawer | 390*385*1100 | 585*685*1340 |
Vertical 400L upper and lower double doors | 500*600*1140 | 600*740*1920 |
Third. Operation and use:
1. After unpacking, check whether the instrument is intact and undamaged, and then place the instrument on a level surface.
2. Check whether the power supply is stable, then plug in the power supply and turn on the switch. At this time, the meter displays the actual temperature in the thermostat. Wait 3 minutes, the compressor will start.
Fourth, Matters needing attention:
1. The instrument cannot be stored and used in an environment with damp and corrosive gas.
2. The first time it is used (when it has not been used for a long time), the machine must work for 2 hours before it can be tested, so as to avoid inaccurate values in the first use.
3. If the power is cut off or out of power for some reason, immediately turn off the power switch. If you need a new start, you must turn it on after 30 minutes, so as not to burn the compressor quickly.
4. It is strictly forbidden to tilt the instrument more than 45% during transportation.
5. When using, it needs to be adjusted by a voltage stabilizer: 220V 50HZ 15A
6. This instrument must be grounded.
7. It is strictly forbidden to run for a long time when not in use.
105L Medical low temperature refrigerator Low temperature refrigerator Freezer refrigerator Vaccine medicine refrigerator -25 degrees Medical freezer Experimental low temperature refrigerator Test low temperature box -25 to 60 degrees 105L-560L